What was found
PIT - DURING Q-2 INSPECTION, FOUND LEVEL II CORROSION SKIN AT STATION 769 LONGERON 28 RT. CLEANED AND TREATED CORRODED AREA AND INSTALLED DOUBLER REPAIR PER SRM 53-04 FIG 53. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-2 INSPECTION, FOUND LEVEL II CORROSION SKIN AT STATION 769 LONGERON 28 RT. CLEANED AND TREATED CORRODED AREA AND INSTALLED DOUBLER REPAIR PER SRM 53-04 FIG 53. (W)