What was found
PIT - DURING Q-2 INSPECTION, FOUND LEVEL II CORROSION REF C58-53301 AT STATION 1344 AFT LEFT GALLEY ATTACHMENT AT FLOOR BEAM 1338 TO AFT PRESSURE BULKHEAD AT FLOOR LEVEL. MANUFACTURED INTERCOSTAL AND REPLACED PER SRM 53-14. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-2 INSPECTION, FOUND LEVEL II CORROSION REF C58-53301 AT STATION 1344 AFT LEFT GALLEY ATTACHMENT AT FLOOR BEAM 1338 TO AFT PRESSURE BULKHEAD AT FLOOR LEVEL. MANUFACTURED INTERCOSTAL AND REPLACED PER SRM 53-14. (W)