What was found
PIT - DURING Q-2 INSPECTION, FOUND DENT 1 INCH BY 1.75 INCH BY .75 INCH DEEP BETWEEN STATION 275 AND 294 LONGERON 23L AND 27L IN SKIN AREA. INSTALLED DOUBLER REPAIR PER SRM 53-04 SH 17 FIG 38. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-2 INSPECTION, FOUND DENT 1 INCH BY 1.75 INCH BY .75 INCH DEEP BETWEEN STATION 275 AND 294 LONGERON 23L AND 27L IN SKIN AREA. INSTALLED DOUBLER REPAIR PER SRM 53-04 SH 17 FIG 38. (W)