What was found
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND SEVERAL 1 INCH BY 1 INCH NUTPLATE HOLES CORRODED, BS 967 RBL 0 TO RBL 50 INCHES. REPAIRED PER SRM 53-00-51, FIG 202. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND SEVERAL 1 INCH BY 1 INCH NUTPLATE HOLES CORRODED, BS 967 RBL 0 TO RBL 50 INCHES. REPAIRED PER SRM 53-00-51, FIG 202. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (W)