What was found
PIT - DURING Q-1 CHECK INSPECTION, FOUND A DENT .075 INCH DEEP .75 INCH LONG AT STATION 983 LONGERON 25L AND 24L. INSTALLED FLUSH DOUBLER REPAIR PER SRM 53-04 FIG 38. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-1 CHECK INSPECTION, FOUND A DENT .075 INCH DEEP .75 INCH LONG AT STATION 983 LONGERON 25L AND 24L. INSTALLED FLUSH DOUBLER REPAIR PER SRM 53-04 FIG 38. (M)