What was found
PIT - DURING Q-1 CHECK INSPECTION, FOUND LEVEL II CORROSION AT STATION 980 LEFT LAV FLOORBEAM, REF C58-53300. REMOVED CORROSION AND INSTALLED FILLER TYPE REPAIR PER USAIR TYPICAL REPAIR 53-10-19 AND SRM 53-05 FIG 20. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-1 CHECK INSPECTION, FOUND LEVEL II CORROSION AT STATION 980 LEFT LAV FLOORBEAM, REF C58-53300. REMOVED CORROSION AND INSTALLED FILLER TYPE REPAIR PER USAIR TYPICAL REPAIR 53-10-19 AND SRM 53-05 FIG 20. (M)