What was found
PIT - DURING Q-1 CHECK INSPECTION, FOUND .25 INCH CRACK AT REAR PRESSURE BULKHEAD STATION 996 TOP RIGHT DOOR FRAME AREA. INSTALLED DOUBLER REPAIR DACO DWG J060088-507. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-1 CHECK INSPECTION, FOUND .25 INCH CRACK AT REAR PRESSURE BULKHEAD STATION 996 TOP RIGHT DOOR FRAME AREA. INSTALLED DOUBLER REPAIR DACO DWG J060088-507. (M)