What was found
PIT - SCHEDULED PRODUCTION CONTROL ITEM. FOUND .75 INCH CRACK STATION 995 BETWEEN LONGERSON 15 AND 16 RIGHT SKIN CLIP. SPLICED NEW SECTION OF SKIN CLIP PER SRM 53-03 FIG 6. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - SCHEDULED PRODUCTION CONTROL ITEM. FOUND .75 INCH CRACK STATION 995 BETWEEN LONGERSON 15 AND 16 RIGHT SKIN CLIP. SPLICED NEW SECTION OF SKIN CLIP PER SRM 53-03 FIG 6. (M)