What was found
PIT - DURING Q-6 CHECK INSPECTION, FOUND LEVEL II CORROSION REF CPCP TASK NR C58-53300 FLOORBEAM TOP ANGLE STATION 1338 RIGHT LAV. ACCOMPLISHED SPLICE REPAIR FLOORBEAM AND REPLACED ANGLE PER USAIR TYPICAL REPAIR 53-10-14. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-6 CHECK INSPECTION, FOUND LEVEL II CORROSION REF CPCP TASK NR C58-53300 FLOORBEAM TOP ANGLE STATION 1338 RIGHT LAV. ACCOMPLISHED SPLICE REPAIR FLOORBEAM AND REPLACED ANGLE PER USAIR TYPICAL REPAIR 53-10-14. (W)