What was found
PIT - DURING Q-6 CHECK INSPECTION, FOUND DENT 2.375 INCH BY 1.75 INCH BY .080 INCH DEEP STATION 296 BETWEEN LONGERON 24L AND 23L. CUT OUT DAMAGED AREA AND INSTALLED INTERNAL FINGER DOUBLER REPAIR PER SRM 53-04 FIG 38. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-6 CHECK INSPECTION, FOUND DENT 2.375 INCH BY 1.75 INCH BY .080 INCH DEEP STATION 296 BETWEEN LONGERON 24L AND 23L. CUT OUT DAMAGED AREA AND INSTALLED INTERNAL FINGER DOUBLER REPAIR PER SRM 53-04 FIG 38. (W)