What was found
PIT - DURING Q-6 CHECK INSPECTION, FOUND 1.5 INCH BY 2 INCH BY .030 INCH DEEP DENT STATION 484 BETWEEN LONGERON 21L AND 22L. CUT OUT DAMAGED AREA AND INSTALLED INTERNAL FINGER DOUBLER REPAIR PER SRM 53-04 FIG 38 VIEW L. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-6 CHECK INSPECTION, FOUND 1.5 INCH BY 2 INCH BY .030 INCH DEEP DENT STATION 484 BETWEEN LONGERON 21L AND 22L. CUT OUT DAMAGED AREA AND INSTALLED INTERNAL FINGER DOUBLER REPAIR PER SRM 53-04 FIG 38 VIEW L. (W)