What was found
IND - DURING CX-2 INSPECTION ACCOMPLISHED SID INSPECTION PSE REF 53.09.001, FOUND .5 INCH CRACK ACROSS LONGERON AT STATION 408 LONGERON 17 RIGHT. ACCOMPLISHED LONGERON SPLICE REPAIR PER SRM 53-02 PG 2A AND USAIR EA 30247. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
IND - DURING CX-2 INSPECTION ACCOMPLISHED SID INSPECTION PSE REF 53.09.001, FOUND .5 INCH CRACK ACROSS LONGERON AT STATION 408 LONGERON 17 RIGHT. ACCOMPLISHED LONGERON SPLICE REPAIR PER SRM 53-02 PG 2A AND USAIR EA 30247. (W)