What was found
IND - DURING SCHEDULED PRODUCTION CONTROL ITEM NR 949, FOUND .125 INCH CRACK IN SKIN OF RIVET STATION 775 LONGERON 1 RT. EDDY CURRENT INSPECTION. ACCOMPLISHED REPAIR IAW SRM 53-04. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
IND - DURING SCHEDULED PRODUCTION CONTROL ITEM NR 949, FOUND .125 INCH CRACK IN SKIN OF RIVET STATION 775 LONGERON 1 RT. EDDY CURRENT INSPECTION. ACCOMPLISHED REPAIR IAW SRM 53-04. (W)