What was found
PIT - DURING SCHEDULED Q-1 INSPECTION, FOUND LEVEL 2 CORROSION. REF, TASK NR C58-5330 STATION 996 LEFT FLOORBEAM. MANUAL FLOORBEAM CAP ANGLE FROM 7075-T6 EXTENSION AND INSTALLED REPAIR ANGLE PER SRM 53-05 FIG 72. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING SCHEDULED Q-1 INSPECTION, FOUND LEVEL 2 CORROSION. REF, TASK NR C58-5330 STATION 996 LEFT FLOORBEAM. MANUAL FLOORBEAM CAP ANGLE FROM 7075-T6 EXTENSION AND INSTALLED REPAIR ANGLE PER SRM 53-05 FIG 72. (M)