What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 60 INCH CORRODED AREA S-17L, BS 312-372 (FORWARD ENTRY DOOR SILL ANGLE). REPAIRED PER SRM 51-10-1. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 60 INCH CORRODED AREA S-17L, BS 312-372 (FORWARD ENTRY DOOR SILL ANGLE). REPAIRED PER SRM 51-10-1. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)