What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND TOTAL AREA OF CORROSION .25 INCH BY 10 INCH, 6 INTERCOSTALS CORRODED AND NUTPLATE HOLES BS 294-344, 3 AT LBL 11 BS 294-344, 3 AT RBL 11 BS 294-344. REPAIRED PER SRM 51-10-1. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)