What was found
INT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND INTERGRANULAR CORROSION (FULL WIDTH OF T-CAP) STATION 986.5 FLOORBEAM FROM 44 LBL TO 44 RBL. REPAIRED PER SRM 51-70-13 EA 39205. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND INTERGRANULAR CORROSION (FULL WIDTH OF T-CAP) STATION 986.5 FLOORBEAM FROM 44 LBL TO 44 RBL. REPAIRED PER SRM 51-70-13 EA 39205. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)