What was found
INT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND APPROX 1 INCH BY 5 INCH CORROSION ON FLOORBEAM AT STATION 947, RBL 12. REPAIRED PER TR 53-10-01A. CORROSION TASK NR C53-107-02, CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND APPROX 1 INCH BY 5 INCH CORROSION ON FLOORBEAM AT STATION 947, RBL 12. REPAIRED PER TR 53-10-01A. CORROSION TASK NR C53-107-02, CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)