What was found
PIT - DURING SCHEDULED Q-4 CHECK INSPECTION, FOUND LEVEL 1 CORROSION STATION 980 FLOOR BEAM RIGHT LAVATORY, TASK NR C57-53300. INSTALLED FILLER AND SUPPORT ANGLE PER SRM 53-10-14. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING SCHEDULED Q-4 CHECK INSPECTION, FOUND LEVEL 1 CORROSION STATION 980 FLOOR BEAM RIGHT LAVATORY, TASK NR C57-53300. INSTALLED FILLER AND SUPPORT ANGLE PER SRM 53-10-14. (M)