What was found
PIT - DURING SCHEDULED Q-4 CHECK INSPECTION, FOUND .25 INCH CRACK AT HI-LOK AT LONGERON 3 LEFT STATION 180. INSTALLED SPLICE REPAIR PER SRM 53-02 FIG 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING SCHEDULED Q-4 CHECK INSPECTION, FOUND .25 INCH CRACK AT HI-LOK AT LONGERON 3 LEFT STATION 180. INSTALLED SPLICE REPAIR PER SRM 53-02 FIG 2. (M)