What was found
PIT - DURING SCHEDULED Q-4 CHECK INSPECTION, FOUND DENT IN BOTTOM OF BULKHEAD STATION 965 RT. INSTALLED DOUBLER REPAIR PER SRM 53-03 FIG 19. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING SCHEDULED Q-4 CHECK INSPECTION, FOUND DENT IN BOTTOM OF BULKHEAD STATION 965 RT. INSTALLED DOUBLER REPAIR PER SRM 53-03 FIG 19. (M)