As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PIT - DURING SCHEDULED Q-4 CHECK INSPECTION, FOUND LEVEL 2 CORROSION OUTBOARD WEB OF FLOORBEAM WHERE IT ATTACHED TO BELTFRAME STATION 996. CORROSION TASK NR C58-53300. REMOVED CORROSION AND INSTALLED REPAIR DOUBLER PER SRM 53-05 FIG 72 AND USAIR EA NR 30252. (M)