What was found
IND - DURING SCHEDULED SID INSPECTION REF: PSE 53.09.009 AND 53.09.010, FOUND A 1 INCH CRACK IN LONGERON 3L AT STATION 680. CUT OUT DAMAGE AND INSTALLED SPLICE REPAIR PER USAIR EA 39338 AND SRM 53-02 FIG 2. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
IND - DURING SCHEDULED SID INSPECTION REF: PSE 53.09.009 AND 53.09.010, FOUND A 1 INCH CRACK IN LONGERON 3L AT STATION 680. CUT OUT DAMAGE AND INSTALLED SPLICE REPAIR PER USAIR EA 39338 AND SRM 53-02 FIG 2. (W)