SDR USAA950649

Service difficulty report · Pump · Doug DC981

Difficulty date
June 29, 1995
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N827US
Make and model
Doug DC981
Aircraft serial
48049
Part
Pump
Part number
AS66411LS666
Condition
Inoperative
Location
Rt
Stage of operation
CR
Nature of condition
K, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

MCO - FLT 944 - EN ROUTE, AC LOST THE RT HYDRAULIC QUANTITY. THE CAPTAIN DECLARED AN EMERGENCY AND LANDED IN MCO WITHOUT INCIDENT. MAINTENANCE REPLACED THE ENGINE DRIVEN PUMP, THE PRESSURE LINE FILTER, THE CASE DRAIN FILTER AND HYDRAULIC SYSTEM RETURN LINE FILTER. OPERATIONS CHECKED GOOD. REF 95ZZZW811, 95ZZZW812, 95ZZZW813.