As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 4 INCHES BY 1 INCH OF CORROSION BS 987.0 BL 40 LT T-CAP SECTION OF FLOORBEAM. FABRICATED NEW T-CAP, STRAP AND REPAIR ANGLES AND INSTALLED SAME. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (W)