What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND CORROSION ON FLOORBEAM 1 INCH BY 12 INCHES STA 328 RBL 6 TO LBL 63. REPLACED UPPER T-CAP, TR 53-10-3. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND CORROSION ON FLOORBEAM 1 INCH BY 12 INCHES STA 328 RBL 6 TO LBL 63. REPLACED UPPER T-CAP, TR 53-10-3. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (W)