INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND 3 CORRODED SCREW HOLES RT AFT LAVATORY FLOOR SUPPORT BS 986.5 PLUS 7 INCHES TO 1006 36 INCHES RBL. FABRICATED NEW SUPPORT SRM 51-10-02 PG 15. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (W)