What was found
INT - DURING 'Q-1' CHECK, VISUAL INSPECTION FOUND .75 INCH BY 1 INCH SEVERAL PLACES CORRODED BS 787 TO BS 847 ON FLOOR ANGLE. CORROSION TASK NR: C53-208-01. CORROSION LEVEL: 2. REPLACED ANGLE, REPAIRED PER SRM 51-10-02. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING 'Q-1' CHECK, VISUAL INSPECTION FOUND .75 INCH BY 1 INCH SEVERAL PLACES CORRODED BS 787 TO BS 847 ON FLOOR ANGLE. CORROSION TASK NR: C53-208-01. CORROSION LEVEL: 2. REPLACED ANGLE, REPAIRED PER SRM 51-10-02. (X)