What was found
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND CORROSION 1 INCH SQUARE TOTAL AREA, BETWEEN BS 967-987 RBL 16 ON INTERCOSTAL. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. REPLACED INTERCOSTAL, REPAIRED PER SRM 51-10-03. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND CORROSION 1 INCH SQUARE TOTAL AREA, BETWEEN BS 967-987 RBL 16 ON INTERCOSTAL. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. REPLACED INTERCOSTAL, REPAIRED PER SRM 51-10-03. (M)