What was found
PIT - DURING Q-4/CX-6 CHECK INSPECTION, FOUND CUSP MEMBRANE CRACKED IN 2 PLACES BOTH 1 INCH LONG AT STATION 1287 LEFT. MFG NEW CUSP MEMBRANE PER SRM 53-05 FIG 79. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-4/CX-6 CHECK INSPECTION, FOUND CUSP MEMBRANE CRACKED IN 2 PLACES BOTH 1 INCH LONG AT STATION 1287 LEFT. MFG NEW CUSP MEMBRANE PER SRM 53-05 FIG 79. (M)