PIT - DURING Q-1/CX-6 CHECK INSPECTION, FOUND LEVEL 2 CORROSION AT STATION 1322 RIGHT LAV FLOOR BEAM. CORROSION TASK NR C58-53308. CUT OUT CORRODED AREA AND INSTALLED FILLER, ANGLE AND DOUBLERS PER USAIR TYPICAL REPAIR 53-10-19. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-1/CX-6 CHECK INSPECTION, FOUND LEVEL 2 CORROSION AT STATION 1322 RIGHT LAV FLOOR BEAM. CORROSION TASK NR C58-53308. CUT OUT CORRODED AREA AND INSTALLED FILLER, ANGLE AND DOUBLERS PER USAIR TYPICAL REPAIR 53-10-19. (M)