What was found
PIT - DURING C-CHECK INSPECTION, FOUND 2 INCH CRACK AND STRINGER NR 68R APPROXIMATELY 4 INCHES AFT OF STATION 3870. INSTALLED SPLICE REPAIR PER SRM 51-70-06 REPAIR NR 5 PG 206. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING C-CHECK INSPECTION, FOUND 2 INCH CRACK AND STRINGER NR 68R APPROXIMATELY 4 INCHES AFT OF STATION 3870. INSTALLED SPLICE REPAIR PER SRM 51-70-06 REPAIR NR 5 PG 206. (M)