PIT - DURING Q-1/CD-6 CHECK INSPECTION, FOUND GOUGE .015 BY 1.75 INCHES LONG AT STATION 755 LONGERON 15R. BLENDED GOUGE, DYE CHECKED AND INSTALLED INTERNAL DOUBLER PER SRM 53-04 FIG 38 VIEW E. (M)