What was found
PIT - DURING Q-1/CX-6 CHECK INSPECTION, FOUND TWO .75 INCH LONGERON CRACKS AT STATION 237 AND 256 LONGERON 17L. INSTALLED SPLICE REPAIR PER SRM 53-02 FIG 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-1/CX-6 CHECK INSPECTION, FOUND TWO .75 INCH LONGERON CRACKS AT STATION 237 AND 256 LONGERON 17L. INSTALLED SPLICE REPAIR PER SRM 53-02 FIG 2. (M)