What was found
PIT - DURING Q-3/CX-2 INSPECTION, FOUND CORROSION 2 INCH BY 2 INCH STATION 980 LEFT LAV INBOARD SCREW HOLE IN FLOOR BEAM. CUT OUT DAMAGED AREA AND INSTALLED FILLERS AND DOUBLER PER SRM 53-10-19. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-3/CX-2 INSPECTION, FOUND CORROSION 2 INCH BY 2 INCH STATION 980 LEFT LAV INBOARD SCREW HOLE IN FLOOR BEAM. CUT OUT DAMAGED AREA AND INSTALLED FILLERS AND DOUBLER PER SRM 53-10-19. (M)