What was found
INT - DURING 'CX-6' CHECK VISUAL INSPECTION, FOUND 4 INCH BY 2 INCH CORRODED AREA BETWEEN STATION 947.5 AND 967 AT S-26L. INSTALLED REPAIR SPLICES. REPAIRED PER SRM 53-10-3. (M)