What was found
PIT - DURING Q-4 CHECK INSPECTION, FOUND LEVEL 2 CORROSION AT STATION 237 LONGERON 29R. REMOVED CORRODED SECTION AND SPLICED IN NEW SECTION OF LONGERON PER SRM 53-02 FIG 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-4 CHECK INSPECTION, FOUND LEVEL 2 CORROSION AT STATION 237 LONGERON 29R. REMOVED CORRODED SECTION AND SPLICED IN NEW SECTION OF LONGERON PER SRM 53-02 FIG 2. (M)