What was found
PIT - DURING Q-4 CHECK INSPECTION, FOUND 1 INCH CRACK LEFT DRAG ANGLE STATION 1474 (CANTED FRAME). STOP DRILLED CRACK AND INSTALLED SKIN AND DOUBLER REPAIR PER SRM 53-05 FIG 23B CONF 7007. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-4 CHECK INSPECTION, FOUND 1 INCH CRACK LEFT DRAG ANGLE STATION 1474 (CANTED FRAME). STOP DRILLED CRACK AND INSTALLED SKIN AND DOUBLER REPAIR PER SRM 53-05 FIG 23B CONF 7007. (M)