As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 25 INCH CORROSION AT BS 857 TO BS 787 ON FLOOR SUPPORT ANGLE. INSTALLED NEW SUPPORT ANGLE SECTION INCLUDING DOUBLER AND FILLER. ALSO, COMPLETED JOGGLE MOD AT STATION 852 SRM 53-00-53 FIG 202. CORROSION TASK NR C53-202-01, CORROSION LEVEL 2. (M)