PIT - DURING Q-5 CHECK INSPECTION, FOUND .25 INCH CRACK LEFT SIDE STATION 1463, DRAG ANGLE. INSTALLED FILLER AND DOUBLER PER SRM 53-05 FIG 23. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-5 CHECK INSPECTION, FOUND .25 INCH CRACK LEFT SIDE STATION 1463, DRAG ANGLE. INSTALLED FILLER AND DOUBLER PER SRM 53-05 FIG 23. (M)