What was found
PIT - DURING Q-5 CHECK INSPECTION, FOUND 1 INCH BY 20 INCH AREA OF LEVEL 1 CORROSION PREVIOUSLY REWORKED AT LONGERON 28L, STATION 1211 TO 1231 CORROSION TASK NR C57-53300. SPLICED IN NEW SECTION OF LONGERON PER SRM 53-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-5 CHECK INSPECTION, FOUND 1 INCH BY 20 INCH AREA OF LEVEL 1 CORROSION PREVIOUSLY REWORKED AT LONGERON 28L, STATION 1211 TO 1231 CORROSION TASK NR C57-53300. SPLICED IN NEW SECTION OF LONGERON PER SRM 53-02. (M)