As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND 2 INCH BY 4 INCH CORROSION BS 947.5 TO BS 967 RBL 45 ON FLOOR BEAM T-CAP. FABRICATED NEW T-CAP 18 INCHES LONG, REPAIRED PER SRM 53-00-51. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (M)