What was found
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND CORROSION 1 INCH BY 18 INCHES STATION 986.5 BL ZERO TO LBL 24 INCHES. REPLACED UPPER T-CAP. REPAIRED PER SRM 53-00-51. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND CORROSION 1 INCH BY 18 INCHES STATION 986.5 BL ZERO TO LBL 24 INCHES. REPLACED UPPER T-CAP. REPAIRED PER SRM 53-00-51. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (M)