What was found
CLT - DURING A MQ6-CHECK INSPECTION, VISUALLY FOUND CORRODED AREAS AROUND FLOOR BOARD ATTACH HOLES 30 INCHES AT STATION 328 FROM LBL TO RBL 55, ON FLOOR BEAM. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. INSTALLED T-CAP (UPPER) PER TYPICAL REPAIR 53-10-03. (M)