What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 2 INCH CORROSION BS 986 RBL 31. CUT OUT CORROSION, INSTALLED FILLERS AND REPAIR ANGLES, REPAIRED PER SRM 53-60-51, FIG 203. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 2 INCH CORROSION BS 986 RBL 31. CUT OUT CORROSION, INSTALLED FILLERS AND REPAIR ANGLES, REPAIRED PER SRM 53-60-51, FIG 203. (M)