What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND SEVERAL .75 INCH BY .5 INCH SPOTS OF CORROSION BS 500G STRINGER 15R TO STRINGER 25L. REPLACED ATTACHED ANGLE, REPAIRED PER DRAWING 65-49631 AND SRM 51-10-2. CORROSION TASK NR C53-208-01, CORROSION LEVEL 2. (M)