What was found
PIT - DURING Q-1 CHECK INSPECTION, FOUND 5 CRACKS .5 INCH TO 1 INCH LONG IN CANTED FRAME STATION 1463, BELOW LONGERON NR 5L AND 5R. CUT OUT SECTION OF DAMAGED AREA AND INSTALLED NEW SECTION PER USAIR EA NR 28127A. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-1 CHECK INSPECTION, FOUND 5 CRACKS .5 INCH TO 1 INCH LONG IN CANTED FRAME STATION 1463, BELOW LONGERON NR 5L AND 5R. CUT OUT SECTION OF DAMAGED AREA AND INSTALLED NEW SECTION PER USAIR EA NR 28127A. (M)