What was found
PIT - DURING Q-1 CHECK INSPECTION, FOUND .5 INCH CRACK IN END OF LONGERON 2L STATION 1401. SPLICED IN NEW SECTION OF LONGERON PER SRM 53-02 FIG 5 AND USAIR EA NR 28221. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-1 CHECK INSPECTION, FOUND .5 INCH CRACK IN END OF LONGERON 2L STATION 1401. SPLICED IN NEW SECTION OF LONGERON PER SRM 53-02 FIG 5 AND USAIR EA NR 28221. (M)