What was found
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 1 INCH BY .15625 DENT, AFT ENTRY DOOR AFT REAR UPPER CORNER. INSTALLED DOUBLER, REPAIRED PER SRM 52-00-01, FIG 206. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 1 INCH BY .15625 DENT, AFT ENTRY DOOR AFT REAR UPPER CORNER. INSTALLED DOUBLER, REPAIRED PER SRM 52-00-01, FIG 206. (M)