What was found
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND 2 INCH CRACK STATION 520 FLOOR BEAM UPPER RADIUS RBL 45, WL 207.75. STOP DRILLED AND INSTALLED DOUBLER REPAIR/MODIFICATION. REPAIRED PER EA 40020. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND 2 INCH CRACK STATION 520 FLOOR BEAM UPPER RADIUS RBL 45, WL 207.75. STOP DRILLED AND INSTALLED DOUBLER REPAIR/MODIFICATION. REPAIRED PER EA 40020. (M)